Load Sharing in a Heater

A winter heater operating at $220\, \text{V}$ mains has settings for normal cold and extreme cold. Normal cold setting delivers $1100\, \text{W}$ output whereas extreme cold setting delivers $2200\, \text{W}$ output. There are two identical resistances connected in parallel inside the heater to attain the objective whose connection is controlled by the external settings knob. Assuming no other energy loss find the value of each resistance $R$. Ignore change is resistance with temperature.

Would it be wise for the company to provide a knob with 3 positions - Normal Cold, Extreme Cold, Normal Cold? 

Solution

When voltage is constant, the formula $P = \frac {V^2}{R_{eq}}$ should be used.

Since power is inversely proportional to $R$, when $R$ is halved, power doubles.

When the two identical resistances are in parallel, the equivalent resistance is halved. This is the situation when $2200\, \text {W}$ power is available.

When only one resistance is part of the circuit, $1100\, \text {W}$ power is available.

So, $1100=\frac {220^2}{R}$

$\therefore R=44 \Omega$

To increase the life of each resistor, taking thermal and electrical wear and tear into account, the knob can have three positions (the underlying idea being load sharing over time):

Normal: One resistor $R$ is part of the circuit.
Extreme: Both resistors are part of the circuit.
Normal: The other resistor $R$ is part of the circuit.